iSMA-B-4I4O-H

4I4O H persp

Multiprotocol I/O module with 4 digital inputs and 4 digital outputs, HOA switches and built-in light applications.

Multiprotocol I/O Module in a Compact Size with Built-in Light Applications
Powerful I/O module that works as a remote I/O over a serial port with open protocols, BACnet MS/TP and Modbus RTU/ASCII. A compact size and ease of installation allow the module to be fitted even into limited space installations. The module is equipped with light applications that control the output based on the input measurement.

4 Digital Inputs
Dry contact inputs were made for monitoring. 100 Hz fast pulse counter with override function saves the real-time values to the EEPROM memory.

4 Digital Outputs
Digital outputs equipped with normally open 3 A relays allow for a direct control without additional relays.

Manual Override Switches
Each output can be manually overridden using a dedicated hand operating switch.

Built-in Light Applications
Light control configurable algorithms make the module applicable as a standalone controller.

Simplified Configuration and Commissioning Process
The module allows for seamless configuration over BACnet, Modbus, or dedicated free of charge tool. The ability to be powered from a USB port facilitates local testing and a straightforward updating process, and the high-end RS485 transceiver allows up to 128 devices to communicate reliably with the client on a single bus.

Quality and Reliability Confirmed by Certificates
iSMA CONTROLLI is a long-standing member of the BACnet community. The experience in developing high quality products and the BTL (BACnet Test Laboratory) certification confirm the excellent performance of communication using the BACnet protocol.
Reliability of operation is confirmed by UL testing, certified by Underwriters Laboratories.


 

Technical Specification

 

Hardware Specification
RS485 interface
mini USB type B interface
Status LED indicators
DIN rail mounted
8 I/Os onboard

Inputs
4 Digital Inputs (DI)
Dry contact inputs
Fast pulse counter up to 100 Hz saved in the EEPROM memory

Outputs
4 Digital Outputs (DO)
NO relay output
Resistive load max. 3 A @ 230 V AC / 30 V DC
Inductive load max. 75 VA @ 230 V AC / 30 W @ 30 V DC

Communication
BACnet MS/TP
Modbus RTU/ASCII
Free software iSMA Configurator
Dedicated Niagara Framework modules

Power Supply
24 V DC ± 20%
24 V AC ± 20%

Outputs typeDigital
Inputs typeDigital
Communication protocolBACnet MS/TP, Modbus RTU/ASCII
Power supply24 V AC, 24 V DC
Controller typeConfigurable
IP40
Digital inputs4
Digital outputs4

 