product, Sensors, Temperature and Humidity

TUTA35 NTC

TUTA35 NTC

Room Relative Humidity and Temperature sensor
Output signal 0 ÷ 10 Vdc and 4 to 20 mA with auto-detection
Degree of protection IP65

The relative humidity transmitters, also available combined with temperature sensor, are used in air conditioning system for the measurement of relative humidity. They measure the relative humidity value to be measured by a capacitive sensitive element whose signal, suitably linearized and amplified, is transformed into a voltage signal (0..10 V) or current (4..20 mA ) at the terminals of output.
in models with temperature sensor the sensing element is constituted by a resistance NTC (10 kΩ).

MeasureRelative Humidity, Temperature
ApplicationRoom
InstallationWall
Sensing elementNTC 10 kOhm
T Fluid min [°C]0
T Fluid max [°C]50
Rh0-95%
Power supply24 V AC, 24 V DC
IP30
Output signal0÷10 Vdc, 4÷20 mA

 

product, Sensors, Temperature and Humidity

TUTD32 NTC

TUTD32 NTC

Temperature and relative humidity transmitter for duct
Probe length 200 mm
Output signal 0 ÷ 10 Vdc / Ohm (temp. Balco) (3 + 2 wires)
IP55 protection rating

The relative humidity transmitters, also available combined with temperature sensor, are used in air conditioning system for the measurement of relative humidity. They measure the relative humidity value to be measured by a capacitive sensitive element whose signal, suitably linearized and amplified, is transformed into a voltage signal (0..10 V) or current (4..20 mA ) at the terminals of output.
in models with temperature sensor the sensing element is constituted by a resistance Balco, NTC (10 kΩ) or PTC (1 kΩ).

 
MeasureRelative Humidity, Temperature
ApplicationDuct
InstallationDuct
Sensing elementNTC 10 kOhm
T Fluid min [°C]0
T Fluid max [°C]50
Rh0-95%
Power supply15 to 25 V DC, 24 V AC
Output signal0÷10 Vdc

 

product, Sensors, Temperature and Humidity

TUTD32N10 NTC

TUTD32N10 NTC

Temperature and relative humidity transmitter for duct
Probe length 200 mm
Output signal 0 ÷ 10 Vdc / Ohm (temp. NTC 10kOhm) (3 + 2 wires)
IP55 protection rating

The relative humidity transmitters, also available combined with temperature sensor, are used in air conditioning system for the measurement of relative humidity. They measure the relative humidity value to be measured by a capacitive sensitive element whose signal, suitably linearized and amplified, is transformed into a voltage signal (0..10 V) or current (4..20 mA ) at the terminals of output.
in models with temperature sensor the sensing element is constituted by a resistance Balco, NTC (10 kΩ) or PTC (1 kΩ).

MeasureRelative Humidity, Temperature
ApplicationDuct
InstallationDuct
Sensing elementNTC 10 kOhm
T Fluid min [°C]0
T Fluid max [°C]50
Rh0-95%
Power supply15 to 25 V DC, 24 V AC
Output signal0÷10 Vdc

 

product, Sensors, Temperature and Humidity

TUTD32P1

TUTD32P1

Temperature and relative humidity transmitter for duct
Probe length 200 mm
Output signal 0 ÷ 10 Vdc / Ohm (temp.1kOhm PTC) (3 + 2 wires)
IP55 protection rating

The relative humidity transmitters, also available combined with temperature sensor, are used in air conditioning system for the measurement of relative humidity. They measure the relative humidity value to be measured by a capacitive sensitive element whose signal, suitably linearized and amplified, is transformed into a voltage signal (0..10 V) or current (4..20 mA ) at the terminals of output.
in models with temperature sensor the sensing element is constituted by a resistance Balco, NTC (10 kΩ) or PTC (1 kΩ).

MeasureRelative Humidity, Temperature
ApplicationDuct
InstallationDuct
Sensing elementPTC 1 kOhm
T Fluid min [°C]0
T Fluid max [°C]50
Rh0-95%
Power supply15 to 25 V DC, 24 V AC
Output signal0÷10 Vdc

 

product, Sensors, Temperature and Humidity

TUTD34 NTC

TUTD34 NTC

Temperature and relative humidity transmitter for duct
Probe length 230 mm
Output signal 0 ÷ 10 Vdc / Ohm (temp.) (3 + 2 wires)
Degree of protection IP65

The relative humidity transmitters, also available combined with temperature sensor, are used in air conditioning system for the measurement of relative humidity. They measure the relative humidity value to be measured by a capacitive sensitive element whose signal, suitably linearized and amplified, is transformed into a voltage signal (0..10 V) or current (4..20 mA ) at the terminals of output.
In models with temperature sensor the sensing element is constituted by a resistance NTC (5 kΩ).

MeasureRelative Humidity, Temperature
ApplicationDuct
InstallationDuct
Sensing elementNTC 5 kOhm
T Fluid min [°C]0
T Fluid max [°C]50
Rh0-95%
Power supply15 to 35 V DC, 24 V AC
IP65
Output signal0÷10 Vdc, 4÷20 mA

 

Air Quality, product, Sensors

TQ-D32-CO2

TQ-D32-CO2

Duct air quality Transmitter
Power supply 24 Vac/dc.
Output signal 0 ÷ 10 Vdc , 4 to 20 mA.
Range of measurement 0 ÷ 100% air quality

The TQ-D32 air quality transmitters are designed to control fresh air flow in air conditioning systems. Two different models are available.
TQ-D32-CO2 determines the air quality through measurement of CO2 concentration (ppm).
The output signal can be used to control fresh air fans and dampers according to the ventilation load. It is equipped with a single output which automatically determines whether to run in current or voltage mode, no more jumpers or switches to worry about.

 
MeasureCO2
ApplicationDuct
InstallationDuct
Sensing elementVOC
Power supply24 V AC, 24 V DC
IP54
Output signal0÷10 Vdc, 4÷20 mA

 

Air Quality, product, Sensors

TQ-D32

TQ-D32

Duct air quality Transmitter
Power supply 24 Vac/dc.
Output signal 0 ÷ 10 Vdc , 4 to 20 mA.
Range of measurement 0 ÷ 100% air quality

The TQ-D32 air quality transmitters are designed to control fresh air flow in air conditioning systems.
TQ-D32 determina la qualità dell’aria attraverso la misurazione di
composti organici volatili (VOC) e altri gas misti.
The output signal can be used to control fresh air fans and dampers according to the ventilation load. It is equipped with a single output which automatically determines whether to run in current or voltage mode, no more jumpers or switches to worry about.

MeasureAir Quality
ApplicationDuct
InstallationDuct
Sensing elementVOC
Working range0÷10 V DC, 4÷20 mA
Power supply24 V AC, 24 V DC
IP54
Output signal0÷10 Vdc, 4÷20 mA

 

Air Quality, product, Sensors

TQ-A31 VOC

TQ-A31 VOC

Ambient air quality transmitter.
Power supply 24 Vac/dc.
Output signal 0 ÷ 10 Vdc.
Range of measurement 0 ÷ 100% of the air quality.

The TQ transmitters are used in air conditioning system for the detection of air quality (presence of human perspiration products, cooking vapors and tobacco smoke, etc.).Do not use for safety applications. In particular, the TQ-A31 model is intended for installation in the environment while the TQ- D31 model in the air duct. The TQ transmitters detect the air quality through a semiconductor sensitive element whose signal, appropriately linearized and amplified, is transformed into a voltage signal (0..10 Vcc ).

MeasureAir Quality
ApplicationRoom
InstallationWall
Sensing elementVOC
Power supply24 V AC, 24 V DC
Output signal0÷10 Vdc

 

Pressure, product, Sensors

TP-D334-MA

TP-D334-MA

Differential pressure transmitter 0 ÷ 62.5 / 125/250 Pa (air) configurable with central 0 with output 4-20 mA , for air and non-aggressive gases.
Maximum static pressure 70 Kpa.
Connectionss PVC with an internal diameter of 6 mm.
IP54.

The TP differential pressure transmitters are used in air conditioning system for the measurement of differential pressure in the environment or in the air duct and in hydraulic distribution system, civil and industrial.
The transmitters detect the pressure value to be measured by means of a sensitive element whose movement is linearized and transformed into an output signal.

ApplicationDuct
InstallationDuct
Working range0÷62,5/125/250 Pa
Power supply12 to 24 V DC
Output signal4÷20 mA

 

Pressure, product, Sensors

TP-D334

TP-D334

Differential pressure transmitter 0 ÷ 62.5 / 125/250 Pa configurable with central 0, for air and non-aggressive gases.
Maximum static pressure 70 Kpa.
for PVC Connectionss with 6 mm internal diameter.
IP54.

The TP differential pressure transmitters are used in air conditioning system for the measurement of differential pressure in the environment or in the air duct and in hydraulic distribution system, civil and industrial.
The transmitters detect the pressure value to be measured by means of a sensitive element whose movement is linearized and transformed into an output signal.

ApplicationDuct
InstallationDuct
Working range0÷62,5/125/250 Pa
Power supply24 V AC, 24 V DC
Output signal0÷10 Vdc, 0÷5 Vdc